on Laerdal LCSU 4 Compact Suction Unit User Guide, Laerdal 3G Plus SimMan Head Skin User Guide. The LEDs have two brightness levels. laerdal suction disposable unit complete system which code Free Standard Shipping within the contiguous U.S. on orders over $100! All product and company names are trademarks or registered trademarks of their respective holders. Earn 1 Rewards point per dollar spent. Start earning, This item might require a License Authorization Form, depending on your state. Learn more, This item is considered a legend device, which means it has special ordering guidelines in certain states. Do not repeatedly block the patient tube for more than 10 seconds at a time at vacuum levels greater than 300 mmHg. An empty Battery must charge up to 5 hours to reach full capacity. Perform the Battery Test. ====== Optional Power/Charging AccessoriesExternal Battery Charger (Cat. Laerdal does not provide Service Parts for this product. NoteThe Canisters and Patient Tubes are all disposable items.Do not attempt to clean or reuse these. 884500)DC Power-cord for connection to vehicle 12V DC is required.Plug the smaller power connector into the LCSU 4 12V DC Power Input Connection. No. 880051/880052). The 300 ml Canister is sealed, with an internal Filter. When the vacuum reaches a minimum of 500 mmHg immediately release the blocking. Turn the unit ON by pressing the/OFF button. 0000012392 00000 n Attach the Patient Tube to Patient Port on the Canister. Dimensions:ersion: 31.5 cm x 33cm x 16 cm (12.4 x 13 x 6.3) Disconnect from the external power supply. Easy to convert between the canister systems. The Canister is disposable and cannot be cleaned. The Laerdal Compact Suction Unit 4 (LCSU 4) comes with one suction tube, but no Yankauer. Canisters and Patient Tubes Dispose of after use. CautionThe LCSU 4 may not achieve the highest vacuum levels when operated at high altitudes. ======= High-efficiency filter kit NoteIf LCSU 4 does not maintain the desired suction performance level, refer to Troubleshooting instructions (see Chapter 7). No part of this website may be reproduced in whole or part without expressed written permission by Life-Assist, Inc. What would you like to name the new list? Battery charging time may be increased when charging below 10 oC. Pay $10.50 for ground shipping on orders under $175. 0000008169 00000 n The Laerdal Suction Unit comes complete with AC and DC charging cords, disposable canister with patient tubing, battery, directions for use, a 5 year warranty on the unit and a 90 day warranty on the battery under normal use. Product images shown are for illustration purposes only. Rechargeable Battery, NiMH, 12 VDC 2 Ah Unless otherwise specified, the information in these User Guides applies to all versions. Orders under $100.00 will be charged a $12.50 shipping and handling fee. Use of this equipment adjacent to or stacked with other equipment should be avoided because it could result in improper operation. With the I-ligh Efficiency Filter Kit in tailed the unit is in accordance with LSO 10079-1. DisposalWhen discarding the LCSU 4, we recommend it be discarded according to local protocol. the filter is I EPA. 5 year limited warranty (excluding the canisters, tubing systems and battery. 0000003921 00000 n H\j0l/L` d (E:>kHQfa68v{?/5viYY~;Svyc4&/sxY{p2w7{}Makc*No|=>6yS-%e|lgMi^|[icT\'#"%o5S\+pMlt`Ye"k,`YYY988:888q | + For Cleaning and Maintenance, see Chapter 6. No-tools-necessary field changeablebattery However, the LCSU 4 cannot be used with LCSU 3 Canisters. Battery Charging NoteUse only Laerdal Battery Cat. Designed for optimal preparation in emergency situations. WarningIf the Canister fills and the shut-off mechanism activates, and you have no spare Canister ready for immediate replacement, shut off LCSU 4 and utilize alternative methods according to the local protocol to clear the patients airway. Unauthorized service attempts, opening, or tampering with the LCSU 4 or its electrical components can damage or disable the device and will void the Limited Warranty. 0000003807 00000 n Disconnect and dispose of Canister and Patient Tube. Verify that the Battery is properly installed and charged. Use of the AC/DC Adapter charger (Cat. Disconnect the LCSU 4 from external power prior to cleaning. +4751511700Fax +4751523557Laerdal, the Laerdal logo, Laerdal CompactSuction Unit and LCSU are trademarks ofLaerdal Medical AS or its affiliates. Plug the AC/ DC Adapter into mains power. Disposal must be carried out in accordance with local environment regulations for waste disposal. Both versions can be purchased with or without RTCA compliance. It is intended for the intermittent operation to remove secretions, blood or vomit from a patients airway to allow ventilation. Expedited shipping options and pricing are available at checkout. Air Flow:>30 LPM Follow the LED Indicator and charge the battery as necessary. gYpVz*. No 886115) is offered as an Optional Accessory. The filter cannot be cleaned or disinfected. 0000105548 00000 n Operation with High-Efficiency Filter KitTo increase filtration efficiency the Vacuum Tube may be replaced with a High-Efficiency Filter Kit (Cat. ====== This product is in compliance with the essential requirements of Council Directive 93/42/EEC Medical Device Directive, as amended by Council Directive 2007/47/EC, class IIa Directions forUse. NoteAll models are shipped with the battery inside the unit, but not connected. Required fields are marked *. 0000010832 00000 n Use of accessories, transducers and cables other than those specified or provided by the manufacturer of this equipment could result in increased electromagnetic emissions or decreased electromagnetic immunity of this equipment and result in improper operation. gYpV:+ Home Laerdal Laerdal LCSU 4 Compact Suction Unit User Guide. Like the professionals who use it, the LCSU4 delivers uncompromising patient care. Approximately 45 minutes (free flow). WARRANTIES AND LIABILITY LIMITS All products sold by Life-Assist, Inc. are intended for use by trained medical personnel. Not intended for use in MRI environments. CREDIT EMC disturbances cannot affect this behavior.No particular actions are required to maintain safety and performance with regard to electromagnetic disturbances for the expected service life. External Battery Charger We area leading manufacturer and supplier of sealed lead-acid batteries. Half illuminated indicates a halfway vacuum level, e.g., 175 is indicated by a fully illuminated 150 and a half-illuminated 200 LED. Use of other than Laerdal brand Battery may result in errors related to the Battery status indicator, reduction of the Battery operation time, failure to effectively operate LCSU 4, and/or give rise to hazards to the operator and/or patient. The Canister is disposable and cannot be cleaned. Vacuum Tube (for 800 ml version) and Wire StandWash by immersing and scrubbing in hand dishwashing liquid or similar. CautionAlways use the 800 ml Canister supplied by Laerdal, which has an internal Filter. AC And DCCords Disconnect the LCSU 4 from external power prior to cleaning. Use only Laerdal accessories supplied directly by Laerdal Medical or one of its authorized distributors to ensure that the LCSU 4 operates satisfactorily. Includes: Suction Unit, AC And DCCords,Disposable Canister and Patient Tubing, Battery, Vacuum Tubing and Directions forUse. Orders under $100 will be charged a $12.50 shipping and handling fee. Proximity fields from RF Wireless communications equipment, 380-3% MIix: 27V/m 430-470 MHz: 28V/m 704-787 Ml-lz: 9V/m 800-960 MHz: 28V/m 1700-1990 MI-I z: 28V/m 2400-2470 MHz: 28V/m 5100-5800 MHz: 9V/m, Conducted disturbances induced by RI fields*, 0% UT; 0,5 cycle At 00, 45, 90, 135, 180, 225, 270 and 315, Electrical transient conduction along supply lines, DC power port, Test pulse severity level: III in Table A2 of ISO 7637-2. The Laerdal Compact Suction Unit 4 300ml version weighs 3.3 lbs, and the 800ml version weighs 4.3 lbs. 0000009255 00000 n +M`%Kx'z"Exsrse UPS Battery Center is in no way implying that any of its products are original equipment manufacturer replacement batteries. 0000026755 00000 n Re-use will lead to an increased risk of cross-contamination, degradation of performance, and/or device malfunction. Apply appropriate suction catheter (not supplied by Laerdal).

Call 800.558.6270 for product expiration date, Replacement Battery for Laerdal Suction Unit, Generic. rated with an efficiency of 99.97% down to a particle size of 0.3 gm. 886113. If suctioning of liquid from the Canister or patient into the pump is suspected, do not use the LCSU 4.

They are for single-patient use only. Ownership and all rightsreserved.Printed in Chinawww.laerdal.com, UNIVET VisionAR Control Unit Whats in the box? 884500) for charging or operation inside an aircraft must be avoided. Carry BagsWipe Bags according to instructions provided above for Main Cabinet. Suction Unit No. New Laerdal Suction Unit. Copyright 2022 Penncare Inc. All rights reserved | Developed & Powered by Two Loon Software, Bag, LSU Side Pouch - for Carrying Case or Unit, Battery, Laerdal Suction Unit (LSU) NiMH -, Carrying Case, LSU Full Cover, - Bag Only, Charger, Laerdal AC/DC Adapter Charger w/o Power Cord -, Wall Bracket Only for LSU, - w/DC Power Cord, Wall Bracket Only for LSU, - w/AC Power Cord, Wall Bracket Only for LSU, - w/o Power Cord. Start earning points today! Vacuum Tubing Do not attempt to use the LCSU 4 if parts are damaged or missing.LCSU 4 800 ml (Cat. However other items can be ordered direct from our wide range of suppliers and manufacturers. Delinquent accounts will be referred for collection. Canister options: This battery meets or exceeds the original manufacturer's specifications. No. Destinations outside of the 2 day shipping zone must be shipped 2nd Day Air and the air freight charges will apply. If a damaged shipment is received, please note the extent of the damage to the carrier at the time of delivery. Anonymous- On Wednesday, 04 November 2020. 0000097073 00000 n Both versions of the Laerdal Compact Suction Unit 4 (LCSU 4) come with a carry case for its size. Cat. No. How much does the Laerdal Compact Suction Unit 4 weigh? Compact, powerful, and reliable, Laerdals newest suction unit combines rugged design with lightweight portability, making it an essential tool for every first responder. WarningIf the Low Battery symbol illuminates, immediately switch to an external power source to avoid interrupting operation.

0000004183 00000 n See Charging Instructions (Chapter 5). Do not use the suction tube or suction adapter without a suction catheter attached. Federal law (USA) restricts the LCSU 4 to sale by or on the order of a physician or other licensed medical authority. Refrigerated items cannot be returned. All other orders are shipped FOB origin and freight charges will be applied at the time of shipment. Our warranty is inclusive of shipping costs and is hassle free, the only warranty of this kind in the marketplace.Physical Dimensions:Nominal Voltage: 12VNominal Capacity: 2.3AhTerminal Type: PCWeight: 2 LbsLength: 7.17" (182 mm)Width: 0.91" (23 mm)Height: 2.40" (61 mm)The replacement battery for theLaerdal LSU Suction Unit consists of (1) High Quality 12V 2.3Ah battery. LCSU 4 300 ml (Cat. Do not attempt to open or disassemble the pump or electrical accessories. Our batteries deliver performance and peace of mind and are used in medical devices, alarm systems, fire panels, mobility devices, solar technologies, Uninterrupted Power Supply (UPS) systems, recreational vehicles, and many other industrial and recreational applications. The battery is warranted for 90 days. Battery run time:Approximately 45 minutes (free flow) 30 minutes for theUS model The Scale illuminates Green to indicate the level of vacuum/suction strength, The Light Blue area indicates reduced suction levels for infants and small children. With a suction range from 50 to 550 mmHg, the LCSU 4 can be adjusted for use in the most challenging situations, whether it be a newborn or adult - ensuring you always have just the right amount of power. Changes or modifications not expressly approved by Laerdal Medical could void the users authority to operate the equipment. Model Description: Battery replacement for theLaerdal LSU Suction UnitCompatibility:Laerdal LSU Suction Unit (12V 2.3Ah)Condition: Brand new stockIncludes: (1) TLV1223PC - 12V 2.3Ah PC Battery (compatible replacement)Warranty: 1 year full replacement warranty included, additional warranty is availableLife time expectancy: 3-5 yearsManufacturer: UPS Battery Center Ltd.The replacement battery for theLaerdal LSU Suction Unit is a high quality battery that is designed to provide excellent performance, durability and long life in your device. Dublin, OH 43016. External AC OperationTo run on mains power, use the AC/DC Adapter Charger.Plug the smaller DC output cord power connector into the LCSU 4 12V DC Power Input Connection. No. The device is fully functioning if it passes this test. 0000002673 00000 n Comment * document.getElementById("comment").setAttribute("id","acdb688e65c7c604316d1834e5d14604");document.getElementById("afe6277d1c").setAttribute("id","comment"); Save my name, email, and website in this browser for the next time I comment.

Sitemap 29