NM Series Actuators Installation Manual. 4. Belimo new generation actuators all employ state-of-the-art halomo sensorless, brushless DC motor technology. 13. A step-by-step guide to installing a Belimo Actuator in the field to a Babcock-Davis Smoke Vent. 3. These models are direct drive actuators that rotate to their energized position when power is applied, and spring return to their fail position when power is disconnected. NFB Series Actuators Installation Manual. When power is applied, the manual mechanism is released and the actuator drives toward the full fail-safe position. belimo tekmar actuator manualzz (IN4007 supplied, Belimo Part number 40155) 18 Actuators with plenum rated cable do not have numbers on wires; use color codes instead. The assembly Multifunctional Technology (MFT): This technology was devel-oped by Belimo for incorporation into our damper and valve actu-ator. LH Linear Series Actuators Installation Manual. 20 All 120 VAC, 230 VAC, and UP actuators use appliance If it is on the correct side, proceed to step #5. Power consumption and input impedance must be observed. 800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN 12 INSTRUCTION MANUAL EV Series Actuators The Bray Series 70 is a quarter turn electric actuator with manual override for use on any quarter turn valve requiring up to 18000 in-lb [2034 Nm] of torque .

5. Flow direction arrows must be correct.

Tighten the universal clamp to the shaft. Belimo Subject: TFB24-SR - Damper Actuator, Modulating, Spring Return, 24 VAC/DC, for 2 to 10 VDC or 4 to 20 mA Control Signal Created Date: QUICK MOUNT VISUAL INSTRUCTION MANUAL PKB and PMB Actuators 1 45 in-lb* 2 * Note: Use brass knockout to remove plastic if included with glandset. Installation Instructions Discover the advantages www.belimo.us SY Series Actuators for Butterfly Valves. ft.) Torque Loading Chart Mechanical Operation The actuator is mounted directly to a damper shaft up to 1.05 in diameter by means of its universal clamp. When using an AF or NF actuator, a 5 offset may be necessary to ensure proper close off. If actuator and linkage are removed, they must be reinstalled correctly. Wire numbers are provided for reference. Installation Instructions Mechanical Installation Standard Mounting 70 60 50 40 30 20 10 0 2 3 46810 579 Damper Area (sq. Disengage the actuator gear train by pressing the manual override button and rotate the clamp until centered. Coupling (4) and Adapter Plate (5) on ORANGE side. ft.) Torque Loading Chart Mechanical Operation The actuator is mounted directly to a damper shaft up to 1.05 in diameter by means of its universal clamp. In various forms to belimo actuator installation instructions up or down and down arrows must. Record and instantly share video messages from your browser. Known for its direct-coupled actuator and innovations in pressure independent control valve technology, Belimo has solutions to maintain an efficient building environment.. About Belimo.Belimo is a world leader in the design and The Belimo actuator can be used for virtually any new or retrofit application. Actuator (representation) These instructions apply to the external field installation of Belimo actuators on Greenheck model VCD Control Dampers.

4 Actuators may also be powered by 24 VDC. TF Actuator 800-543-9038 USA BE-LIMO Assembl Orientation Fail Open Fail Closed Coupling (l) and Adapter Plate (5) on GRAY side. Belimo actuators should be mounted indoors in a dry, relatively clean environment free from corrosive fumes. 5 Only connect common to neg. Typical Specification Proportional fire and smoke spring return damper actuators shall be direct coupled type which require no crank arm and linkage and be capable of direct mounting to a jackshaft up to a 1.05 diameter. Belimo Actuator NVF24-MFT-E-50 Belimo Actuator: Model# NVF24-MFT-E-50 1/2" 24 AC/DC 50/60 Hz 10 VA 5.5W 180 LB-F Nema 2 PLEASE VISIT OUR STORE FOR OTHER GREAT DEALS! the actuator ONE-HALF the distance to its full CCW travel. Tighten all fasteners. About Belimo.Belimo is a world leader in the design and manufacturing of damper actuators and control valves used in commercial HVAC systems. ccv in 203-7M-83g6 LATIN AMERICA / CARIBBEAN Align ribs on Coupling with the slots Hollow Axle. Place the actuator in the desired mounting position. The actuator must be rotated so that the valve seats properly for close off. 11. NFX Series Actuators Installation Manual. The Belimo actuator can be used for virtually any new or retrofit application. 7 A 500 (ZG-R01) converts the 4 to 20 mA control signal to 2 to 10 VDC. Belimo actuators should be mounted indoors in dry, relatively clean environment free from corrosive fumes. If the actuator is to be mounted outdoors, a protective enclosure must be used to shield the actuator (SeeBelimo Mechanical Acces- soriess). Tools Required: Wrenches: (1) 3 8 in., (1) 7 Temperature the replacement actuator shall have been UL555S tested at the same or better temperature as the original actuator. 6. (-) leg of control circuits. 3 ft-lbs O-ring PG11 Metric Thread 1/2 NPT 3 4 7 6 5 4 - 6mm 6 - 8mm 8 - 10mm 4 2 1 2 3 5 ** Note: Only use conduit connector provided by Belimo. If not, go to the Short Shaft Installation section. Installation Instructions Mechanical Installation Standard Mounting 70 60 50 40 30 20 10 0 2 3 46810 579 Damper Area (sq. 12. While it is not detailed in codes, the following rules should be followed for selecting Belimo actuators for replacement: Check the technical specifications to ensure an equal or better actuator is used. A crankarm and sever- Simple direct mounting Straightforward direct mounting on the ball valve with only one central screw. The Belimo TFB, Belimo LF, Belimo NFB, Belimo AFB, and Belimo EFB Series direct-coupled air damper actuators provide control of dampers and valves for spring return applications. Tighten the actuators shaft clamp nuts securely. Slide the anti-rotation strap up under the actuator so it engages the actuator at the center of the cutout. The -S model actuators are equipped with an adjustable auxiliary switch used to indicate damper position or to interface additional controls or equipment. Switching positions can be set over the full 0 to 95 rotation simply by setting a switch on the actuator. 1. Set desired switch position. (Example 60%) 2. 11 Actuators may be connected in parallel if not mechanically mounted to the same shaft. Non-Spring Return Items in your download folder Actuators. Title: WTF.1_US-1 The actuator internal common reference is not compatible. Installation Instructions Mechanical Installation min 3-5/16 [84] Meets cULus or UL and CSA requirements.

Power consumption and input impedance must be observed. A crankarm and sever- Belimo Download Center offers one central location to access datasheets, manuals, brochures, installation instructions, software, CAD/REVIT models, videos and more. Installation Instructions Mechanical Installation Mechanical Angle of Rotation Limiting The LF actuators are provided with an adjustable stop to limit the rotation of the actuator. 3 Actuators may also be powered by 24 VDC. Local codes may vary. Actuators . The actuator switches off for seven seconds in the case of blocking, then attempts to restart. Installation, commissioning, operation and mainte-nance must be performed under strict observation of all applicable codes, standards and safety regulations. Rotate the damper to its fail-safe position. Power consumption and input impedance must be observed. rotate the actuator approximately 5 in the direction which would open the damper. For actuator wiring information and diagrams, refer to Belimo Wiring Guide. The damper actuators come in two-position, tri-state, proportional, and Multi-Function Technology (MFT) models. If the actuator is to be mounted outdoors, a protective 34 V8.3 04.2015Subject to modification UL marked actuators is optional, please contact your local Sales Representative for details. Press down which turn 90 degrees to lock with override did the clamp. Learn how to successfully mount and set the open and closed contacts on the S1A / S2A auxiliary switches. If the clamp is not on the correct side as determined in step #1, re-mount the clamp as follows. ft.) orque Loading (in-lb/ sq. Check input signal with a digital volt meter (DVM). Make sure the input is within the range of the actuator. For LF24-SR US this is 2 to 10 VDC or 4 to 20 mA. Note: The input signal must be above the 2 VDC or 4 mA to have the actuator move. Input voltage or current should be 1% of what controller's adjustment or programming indicate. The actuator moves the damper to its normal working position. 71694-00001 CQ Actuators with ZoneTight Zone Valves installation instructions Author: Belimo Subject: 71694-00001 CQ Actuators with ZoneTight Zone Valves installation instructions Keywords: 71694-00001 CQ Actuators with ZoneTight Zone Valves installation instructions Created Date: 8/19/2015 10:21:31 AM During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. High functional reliability The actuator is overload protected and automatically stops when the end stop is reached. 18 Actuators with plenum rated cable do not have numbers on wires; use color codes instead. Actuators may be connected in parallel. Actuators may be connected in parallel. Up to 2 actuators may be connected in parallel. Auction includes: Belimo EFB24-SR Spring Return Actuator Manual Original Box Guarantee: 30 Day satisfaction guarantee. Y=0 Y=0 Standard Mounting NOTE: The EFB, EFXseries actuator is shipped with the manual override 800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA 2 SY1 The NEC mandates that 24 VAC over 100 VA power requires CLASS 1 wiring conduit. NKQ Series Actuators Installation Manual. Typical Specification Proportional fire and smoke spring return damper actuators shall be direct coupled type which require no crank arm and linkage and be capable of direct mounting to a jackshaft up to a 1.05 diameter. Do NOT mix CLASS 1 & CLASS 2 circuits in the same conduit. max. 71694-00001 CQ Actuators with ZoneTight Zone Valves installation instructions Author: Belimo Subject: 71694-00001 CQ Actuators with ZoneTight Zone Valves installation instructions Keywords: 71694-00001 CQ Actuators with ZoneTight Zone Valves installation instructions Created Date: 3/25/2015 10:36:48 AM 3. These models are direct drive actuators that rotate to their energized position when power is applied, and spring return to their fail position when power is disconnected. Belimo Download Center offers one central location to access Belimo Download Center offers one central location to access datasheets, manuals, brochures, installation instructions, software, CAD models, videos and more. Auction includes: Belimo EFB24-SR Spring Return Actuator Manual Original Box Guarantee: 30 Day satisfaction guarantee. This function works in conjunction with the universal clamp or the optional position indicator. 18 Actuators with plenum rated cable do not have numbers 866-805-708g CANADA .

Manual override Manual override possible with lever (the gearing is disengaged as long as the self-resetting lever is pressed). 3 ft. appliance cable and conduit connector eases installation. Hand tighten the two nuts on the actuators universal clamp. ft.) orque Loading (in-lb/ sq. The halomo technology was Manual override crank speeds installation (TAF Series). Installation Instructions Mechanical Installation extends at least 1/8 through the clamp, mount the actuator as follows. Actuator position: 50% Phasecut: An actuator drives depending on the power result of a remaining wave.This signal type cuts the amplitude of the wave and the actuator recognizes this signal as a proportional movement. This procedure balances the valve travel limits within the range of motion of the actuator, thereby assuring unimpeded valve stem travel. These instructions apply to the external field installation of Belimo actuators on Greenheck model VCD Control Dampers. The actuator is shipped at +5 (5 from full fail-safe) to provide automatic compression against damper gaskets for tight shut-off. LU Series Actuators Installation Manual. Install valve with the proper ports as inlets and outlets. Installation Instructions Quick-Mount Visual Instructions for Mechanical Installation Quick-Mount Visual Instructions 1. For actuator wiring information and diagrams, refer to Belimo Wiring Guide. Service tool for parametrisable and communicative Belimo actuators / VAV controller and HVAC performance devices ZTH EU Electrical installation PRCA-S2-T-200 Rotary actuator, Open-close, 3-point, AC 24240 V / DC 24125 V, 160 Nm, Running time motor 35 s Safety notes 2 PRCA-S2-T-200 en-gb 2017-03-21 subject to changes www.belimo.eu! 3. Blow out all piping and thoroughly clean before valve installation. Install grooved side down. Rotate the actuator to apply pressure to the damper seals (b) and re-engage the anti-rotation strap (c). Belimo Actuator NVF24-MFT-E-50 Belimo Actuator: Model# NVF24-MFT-E-50 1/2" 24 AC/DC 50/60 Hz 10 VA 5.5W 180 LB-F Nema 2 PLEASE VISIT OUR STORE FOR OTHER GREAT DEALS! 3 Actuators are provided with color coded wires. NF Series Actuators NEMA 4 Enclosure Installation Manual.

Sitemap 29