Morton Water Softener Installation & Operation Manual.

34). It can negatively affect the taste of food, drinking water, and other beverages.

*Capacity to reduce clear water iron is substantiated by laboratory test data. Make the valve drain line as short and direct as possible.

minimum tube) and 1/2 tubing from your local hardware store. Whether youre looking to remove iron and fight buildup or extend your water softeners life, Morton has the right salt for you.

on MORTIN Water Softener Instruction Manual, Programming the Water Softener (Models M20, M27, M30 & MC30), Programming the Water Softener (Model M34), ELRO Water Detector FW380111R Instruction Manual, LOREX W881AA Series 4K Wi-Fi Smart Deterrence Camera User Guide, LG HBS-FN7 Tone Free Bluetooth Stereo Earbuds User Manual, artika FM-ED-HD2GD LED Ceiling Light Instruction Manual, SAMSUNG ME21R7051SS Range Microwave Oven Instruction Manual, ThermoMart DTXG PID Temperature Controller Instruction Manual, ZERFUN G8 Pro Wireless Microphone System User Manual, Airrex Infrared Heater AH-200/300/800 User Manual, 2017 Toyota Camry Hybrid LE Fuse Box Diagrams, 2017 Mitsubishi Lancer 4WD Fuse Box Diagrams, Mitsubishi Lancer Passenger and Engine Fuse Box Diagram, Mira Honesty ERD Bar Valve and Fittings User Manual, Rated Softening Capacity (Grains @ Salt Dose). Excessive sun heat may cause distortion or other damage to metallic parts. See Figures 7 & 8. Operational efficiency is the actual efficiency after the system has been installed. When power is restored, you must reset the present time only if the display is flashing. This can easily be corrected by performing a special regeneration process. To avoid the loss of small parts, we suggest you keep the small parts in the parts bag until you are ready to use them. Secure drain hose. Pour the solution into the tank, and put top cap back on. Purchase a compression fitting (1/4 NPT x 1/2 in. An obstructed flow indicates a plugged top distributor, backwash flow plug, or drain hose. Press the UP or DOWN buttons to set the present time. Place bypass valve(s) in service or soft water position exactly as follows: After about three minutes, open a hot water faucet until there is a steady flow and there are no air bubbles, then close this faucet. (6 tablespoons) of household bleach into the softener brinewell. The Proper Order To Install Water Treatment Equipment. Founded in 2004, we are the leading developer of portable water softening and water deionization products. These models are efficiency rated. box of iodized/non-iodized salt for the Standard model.- Two full 26 oz. Install the softeners top cover and salt lid. The installation must conform to them.

At times of greater than normal water use, such as when you have guests, you could run out of conditioned water before the next scheduled recharge. To change the length of the Backwash: Low Salt Light / Clean ReminderWhen the water softener is connected to electrical power, the light on the control panel will operate as follows: This is a reminder to use Morton MWSC Water Softener Cleanser three times a year. This water softener will reduce moderate amounts of this type of iron (see specifications).

5600sxt softener fleck valve programming button water efficiency max buttons enter controller master menu Close the main water supply valve, located near the good pump or water meter.

Once in this display, press the SELECT button once and one of the two displays in Figure 22 is shown.

boxes of iodized/non-iodized salt for the Double Standard Model.- Four full 26 oz. Step 1: Turn off the water supply.Step 2: Disconnect inlet andoutlet hose from thesoftener.Step 3: You can drain water by tilting unit over or turning it upside down with the head/cap ON. *The 5-digit date code is the middle part of the serial number on the rating decal (Example: M300012-20309-1001). After extended periods of non-use, sanitize the unit by following the instructions below: Step 1: Perform Back-flush, and then completely drain all water from the tank.Step 2: Mix 1 packet (.25 fl oz) of Sani-System with two gallons of water (Sani-System packet cannot be reused). Refer to warranty and elsewhere in this manual for further details on installation and maintenance, parts and service, user responsibility, and further restrictions, or limitations to the use of the product. DO NOT remove the material from inside the tank. Iron in water is measured in parts per million(ppm). If it should become plugged with sand, silt, dirt, etc., the water softener will not work, and hard water will result. Also, inspect and note any damage to the shipping carton. Allow the softener to rinse for a few minutes to flush out any brine that may remain in the resin tank from the brining cycle test. Do not scratch, misshape, etc., surfaces of the nozzle & venturi. Valve Drain RequirementsUsing the flexible drain hose (included), measure and cut to the length needed.

EXTEND YOUR WARRANTY: Use MortonMWSC Water Softener CleanserThe factory warranty for your water softener is shown below. Use one or both of our premium formula pellets in any water softener for the best results. Press and hold the SELECT button until one of the screens in Figure 21 is displayed. 28,100 @ 11.2 lbs. For a period of one (1) year from the date of purchase, all other parts will be free of defects in material and workmanship. Refilling with SaltLift the salt lid and check the salt storage level frequently. Take a broom handle, or as a tool, and hold it next to the water softener. This iron is visible. Step 13. Plug the inlet and outlet with clean rags to keep dirt, bugs, etc.

WARRANTORS SOLE LIABILITY FOR ANY PRODUCT IS LIMITED TO THE REPAIR OR REPLACEMENT OF SUCH PRODUCT, OR A REFUND OF THE PURCHASE PRICE ACTUALLY RECEIVED BY WARRANTOR FOR SUCH PRODUCT, AT WARRANTORS SOLE DISCRETION. NOTE: See valve drain options on pages 7 & 8. This flushes any resin dust out. Visually check and remove any debris from the water softener valve inlet and outlet ports. If a leak occurs at a clip, depressurize the. Press the ELECT button three times, to return to the normal run display (See Figure 23). If a hard object is felt before the pencil mark is even with the top, its most likely a salt bridge. Call Toll Free 1-888-64 WATER (1-888-649-2837) or visit www.mortonwatersofteners.comWhen you call, please be prepared to provide the model and serial number, found on the rating decal, located on the rim below the salt lid hinges. Open salt lid, remove the brinewell cover, and pour about 3 oz. If the time is flashing after a long power outage, the softener continues to work as it should to provide you with soft water. Do not use any sharp or pointed objects as you may puncture the brine tank. CAUTION: The house cold water pipe (metal only) is often used as a ground for the house electrical system, The 3-valve bypass type of installation, shown in Figure 8, will maintain ground continuity. Step 12. Step 1. To change the length of the Backwash: Adjustable Fast RinseTo change the length of the Fast Rinse: CustomizingFeatures / Options(All Models).

NOTE: Press buttons and quickly release them to slowly advance the display. WATER SOFTENER LIMITED WARRANTYWarrantor guarantees, to the original owner, that: If during such respective period, a part proves to be defective, Warrantor will ship a replacement part, directly to your home, without charge. Press and hold the SELECT button until the screen in Figure 40 is displayed. To figure out the approximate capacity of your unit, take the grains of the unit (Standard 8,000/Double 16,000) and divide that by the grains per gallon (GPG)of the water source.Standard Softener8,000 / 11 GPG = 727 gallons8,000 / 58 GPG = 137 gallons, Double Standard Softener16,000 / 11 GPG = 1,454 gallons16,000 / 58 GPG= 275gallons. If needed, use a small brush to remove iron or dirt. 73 & 74, Nozzle & Venturi Assembly (includes Key Nos. This water softener is manufactured by Water Channel Partners, 1890 Woodlane Drive, Woodbury, MN 55125. See the Air Gap Requirements section. Use the RECHARGE button to manually advance the valve into each cycle and check the correct witch operation. The water softener works on 24V DC electrical power, supplied by a direct plug-in power supply (included). The water softener requires a minimum water flow of 3 gallons per minute at the inlet.

This softener setting is shipped in the OFF position, which utilizes the maximum rated capacity while most often achieving maximum salt efficiencies.

measure the distance from the floor to the rim of the water softener. For a period of ten (10) years from the date of purchase, the salt storage tank and fiberglass mineral tank will not rust, corrode, leak, burst, or fail to perform to their specifications. Plugin the Power SupplyDuring installation, the water softener wiring may be moved or jostled from the place. Questions? If you want water in the house pipes again, reopen the shut-off valve on the main water pipe. These softeners conform to NSF/ANSI 44 for the specific performance claims as verified and substantiated by test data.

Consider all of the following when selecting an installation location for the water softener. Step 10. 55-59), Bypass Valve Assembly, 3/4, in- cluding 2 O-Rings (See Key No. Add 5 to the hardness number for each 1 ppm of iron.

If not already done, put a light coating of silicone grease on the single bypass valve o-rings. When installing this unit in the State of California, you MUST turn his setting to the ON position, which may initiate more frequent charges. Your Morton Water Softener has a High Efficiency feature with an ON or OFF setting. Run the drain hose (or a rigid line) to the floor drain. Carefully replace all parts in the correct order. Before placing the unit in storage or being idle for extended periods: Inlet / Outlet Plumbing OptionsAlways install either a single bypass valve (provided), as shown in Figure 7, or, if desired, parts for a 3 valve bypass system (not included) can be purchased and assembled, as shown in Figure 8. Home MORTIN MORTIN Water Softener Instruction Manual, Water SoftenerModels M20, M27, M30, M34 & MC30How to install, operate and maintain your Demand Controlled Water Softener. Colloidal iron water usually has a yellow appearance when drawn. Back flush your Standard Softener every 3 months for 2-5 minutes, Double Standard Softener for 5-10 minutes, and 10-15 minutes for the Park Model Water Softener. (If the flow completely stops, turn the water off, tap the tank against the ground to get the resin to fall back down, and turn the water on 75% full stream.) Comment document.getElementById("comment").setAttribute("id","ab571640b7f6c659d8d318a640f07da2");document.getElementById("afe6277d1c").setAttribute("id","comment"); Save my name, email, and website in this browser for the next time I comment.

Move the softener close to the drain. If you go too long before performing the regeneration process, a few things couldhappen: your unit may not last verylong, or, after the regeneration process, the strips will not test between 0-3 GPG at the output of the softener.

For the Standard model, use only one gallon of the solution with your unit and discard the rest per Sani-System instructions. The total* ppm of iron, and type or types*, is determined by chemical analysis. Add Morton System Saver II Pellets to the storage tank. Step 6: Replace cap andinlet hose to inlet side of softener. Be sure AM or PM is correct.

A licensed plumber shall be used for this installation.

Resetting to Factory DefaultsTo reset the electronic controller to its factory default for all settings (time, hardness, etc. In the state of California: You must turn the Salt Efficiency Feature setting to ON. Your demand water softener will automatically regenerate when it needs to, based on water usage. Set Time of DayIf the words PRESENT TIME do not show in the display, press the SELECT button until they do.

This small component creates the suction to move brine from the brine tank, into the resin tank.

Remove and discard (or recycle) all packing materials. Press the SELECT button once ore to complete the initial programming. To reset the timer, press any button on the control panel and CLEAn will disappear. Check that the drain can adequately handle the flow and volume. NOTE: Check local plumbing and electrical codes for proper installation of the ground wire. If the storage tank is full of salt, it is difficult to tell if you have a salt bridge. Manufactured and warranted by Water Channel Partners 1890 Woodlane Drive Woodbury, MN 55125, Protect your new water softener with Morton Clean and Protect or Morton Clean and Protect Plus Rust Defense Pellets. f the water level does not drop after a recharge, the problem has not been resolved. If water does not enter the tank, look for an obstructed nozzle, venturi, fill flow plug, brine tubing, or brine valve riser pipe.

During installation, unsnap and remove the top cover, together with the salt lid, to expose the softener valve assembly. Program the SoftenerWhen the power supply is plugged into the electrical outlet, the model code and a software version number (example: J3.9), are briefly shown in the display. Press and hold the SELECT button until the screen in Figure 26 is displayed. This water softener will not remove colloidal iron.In some instances, treatment may improve colloidal iron water. Electronic Control Board (PWA), Models M20, M27, M30 & MC30, Reply. Sanitizing the SoftenerCare is taken at the factory to keep your unit clean and sanitary.

water softener pex installing warranty instructions installation softener softeners harveys f15

Sitemap 10