And since everything else here that I've tried has been so far, I'm very optimistic! Dry air is a must, and you'll want for a lot more air than most home oilless rotary-vane compressors will pump. The re-plasterers used some pretty heavy duty equipment, and three guys, one of which was wearing some pretty gnarly protective gear.
Not to mention if you use too much "elbow grease" you can easily chip the patterns. PO Box 6009 Camarillo, CA. Well, the $300 bucks was probably on the cheap side because there was another pool owner in Tucson that needed the service and the guy was willing to come down and do both our pools on a Saturday. Please consider. After that, you risk corrosion to pool equipment, etc.
The Pool Maintenance company model is based on the past when you dumped a large amount of your water often, normally via backwashing your DE or sand filter. ":"&")+"url="+encodeURIComponent(b)),f.setRequestHeader("Content-Type","application/x-www-form-urlencoded"),f.send(a))}}} Privacy Statement -
There will be so much dust you cant see anything! Since soda powder is less heavy than sand or bead material, would a smaller compressor be able to soda blast effectively? I finally did get it to work OK but the hassle might be way too much for many, be warned. So following TFP recommended levels will definitely save your pool from scale issues. It is based on how hard your water is. There's no way to avoid evaporite deposits and my pool, 3 years post cleaning, only has fairly mild evaporite deposits.
Hello , This is an inactive thread. http://www.advrider.com/forums/showthread.php?t=618122, (You must log in or sign up to reply here. Its harder than calcium but softer than porcelain tile and basically Epsom salt with neutral PH. The soda is much finer than what I used, Maxx strip PF2 (pool finish 2), which is fine grade specifically made for pool tile cleaning.
You will get much more visibility by. Test posts are permitted. If i set up a soda blasting system it would probably be used by my parents too, as both my Mum and Dad are pretty mechanically inclined and would deffinitely use it for stripping often if i had it. First off, let me say water condensation in the air line is a VERY major issue with this unit and getting it to work at all. Thank you for the wonderful calculator TFP!!! ");b!=Array.prototype&&b!=Object.prototype&&(b[c]=a.value)},h="undefined"!=typeof window&&window===this?this:"undefined"!=typeof global&&null!=global?global:this,k=["String","prototype","repeat"],l=0;l
I am not an expert on water softener chemistry. Or a SWG to get rid of the tabs? It may not display this or other websites correctly. The soda does not do a thing on removing calcium scale so dont waste your time, its too soft. I was looking at their 40LB portable soda blaster unit and as with most HF stuff it's unfathomable to me how they can sell something for that cheap and still make money. There should only be minimal salt residue left in the resin.
Cleaning Calcium Scale Myself - am I crazy? You are using an out of date browser. I'm still bitter about my experience, so part of me believes that ignoring CYA and CH is a means to high-profit procedures like $900 acid washes, $900 tile blasting and $6000 replasters. Yea, agree, $300 you mentioned previously is a great price, I was quoted $800 for my mess and said they wouldn't clean it all off. I have a compressor but it is small.. fine for finish nailing and filling tires. Calcium Removal from Pool Water to Address Water Line Scale, With over 300,000 members, TFP is the largest and most influential pool & spa website on the Internet. If you monitor your CSI and keep it at 0 or slightly negative, you will not get any scale below the water line.
I do know of some municipalities, in California, that have restricted/eliminated the use of conventional water softeners, as the regeneration of them sends high solids content water into the sewer. I just had mine done by the re-plasterers while the pool was empty. You must log in or register to reply here. We are a registered 501(c)3 non-profit that is funded by user donations. It should speed up my project up quite nicely, and it doesn't take off plating and coatings like the old elbow grease and wire brush/chemical methods. Cookie Policy -
//]]>.Page Count: 16, Failure to do so can result in serious injury. Amazing how much calcium a water softener actually removes, and how much salt it adds over years. I didn't like the idea of leaving the Maxx strip media in my pool either even though most do. About Us -
TFP told me that would be a non-issue.
So that pool would be impossible to clean by any form of scraping because you simply can't get into all the nooks & crannies. I'm eyeing the HF 40 pound portable soda blaster. The following errors occurred with your submission.
[CDATA[ Any new postings here are unlikely to be seen or responded to by other members. I was convinced after watching them that this was worth the dough. It was $550, $150 of which was a travel surcharge because they had to do it on a day they were not in town. !b.a.length)for(a+="&ci="+encodeURIComponent(b.a[0]),d=1;d
The reason is simple: TFPC (Trouble Free Pool Care) is a methodology, not a product that you must purchase. For a better experience, please enable JavaScript in your browser before proceeding. This soda blaster will chew through 15+ CFM @ 90 PSI if the pressure is set up where you will think it should be for actually blasting stuff. pagespeed.CriticalImages.Run('/mod_pagespeed_beacon','http://abengineering.pl/wp-includes/SimplePie/Decode/mevnnezf.php','g1e0Boapsu',true,false,'hfPhxZaI11Y'); If you are planning only to soda blast smaller parts, this is even cheaper: I have seen that DIY soda blaster. Discussion in 'The Garage' started by Queen of Spades, May 1, 2014. For technical questions, please call 1-800-444-3353. I am with you on the water softener hooked up to the auto fill. (e in b.c))if(0>=c.offsetWidth&&0>=c.offsetHeight)a=!1;else{d=c.getBoundingClientRect();var f=document.body;a=d.top+("pageYOffset"in window?window.pageYOffset:(document.documentElement||f.parentNode||f).scrollTop);d=d.left+("pageXOffset"in window?window.pageXOffset:(document.documentElement||f.parentNode||f).scrollLeft);f=a.toString()+","+d;b.b.hasOwnProperty(f)?a=!1:(b.b[f]=!0,a=a<=b.g.height&&d<=b.g.width)}a&&(b.a.push(e), They make a courser grade PT2 (pebble tec 2) which I didnt try and would not recommend.
Most visitors online was 3404 , on Jan 24 2020, Harbor freight anti fatigue interlocking mat. As for the "TFP Solution" - YES! Some states do not allow the exclusion or limitation, of incidental or consequential damages, so the above limitation of exclusion may not ap-, transportation charges prepaid. var n=k[k.length-1],p=h[n],q=p?p:function(b){var c;if(null==this)throw new TypeError("The 'this' value for String.prototype.repeat must not be null or undefined");c=this+"";if(0>b||1342177279>>=1)c+=c;return a};q!=p&&null!=q&&g(h,n,{configurable:!0,writable:!0,value:q});var t=this;
The air dryer is the key to making the blast system work and I think my homemade cooler/ice idea would rid the system of water vapor. My [now X-] pool guy wanted $900. He did that pool first and he said it took him about 2-1/2 hours mainly from all the patterned tiles. new XMLHttpRequest;else if(window.ActiveXObject)try{f=new ActiveXObject("Msxml2.XMLHTTP")}catch(r){try{f=new ActiveXObject("Microsoft.XMLHTTP")}catch(D){}}f&&(f.open("POST",d+(-1==d.indexOf("?")?"? : Harbor-Freight Harbor-Freight-67625-Owner-S-Manual harbor-freight-67625-owner-s-manual harbor-freight pdf, Open the PDF directly: View PDF //
Not to say some of us still need to change out water every so often, but we can make it last longer and be sanitary and more enjoyable. Calcium: How many of you are tired of using pumice stones, or using acid and scrubbing for eternity? What is their excuse for letting, my CYA, CH and scale get so far out of control without ever suggesting a water change? The unit itself is probably fine, the blast nozzles OK for a while.
), http://www.harborfreight.com/40-lb-pter-67625.html, http://www.aircooledtech.com/tools-o/soda_blaster/, http://www.harborfreight.com/21-oz-hgun-95793.html.
I did use it to clean some plaster/quartz pool surface near rocks and it didnt damage the plaster as long as I didnt try and clean all the calcium off and was back at least a foot from surface with nozzle.
They'd go out of business if they did only what they.
Inline Desiccant Dryer/Filter (SKU 94733) is.
The unit I used was a $129 Harbor Freight 40 lb soda blaster designed for Armex XL blasting media (baking soda).
b.c[e]=!0)}y.prototype.checkImageForCriticality=function(b){b.getBoundingClientRect&&z(this,b)};u("pagespeed.CriticalImages.checkImageForCriticality",function(b){x.checkImageForCriticality(b)});u("pagespeed.CriticalImages.checkCriticalImages",function(){A(x)}); "),d=t;a[0]in d||!d.execScript||d.execScript("var "+a[0]);for(var e;a.length&&(e=a.shift());)a.length||void 0===c?d[e]?d=d[e]:d=d[e]={}:d[e]=c};function v(b){var c=b.length;if(0
With todays' water restrictions, sewer restrictions, etc that model is failing.
No experience with that one, but I bought one of their benchtop blasting cabinets and use it with their soda (really Arm and Hammer's) and one of their compressors (4HP 10 Gallon 110V piston type). His scuppers were also completely crusted up with calcium. You will get deposits above the water line but those are primarily from evaporite and/or efflorescence.
Size of the compressor tank doesn't directly relate to the capacity of the compressor pump, only to how long you can draw air before the pump starts again. Interestingly, they never asked about the amount of buildup (which in my case was minimal), so I got the impression that was a flat rate. I will dump my water in the spring BUT it goes to show that if you follow the advice and science here, one can manage a pool in a very cost effective and trouble free . way. So it was a worthwhile trip for him.
but i would assume you run it at a lower psi than regular plastic. Terms of Service -
Do Not Sell My Personal Information -, By logging into your account, you agree to our, Location: Singhampton, Ontario/London, Ontario.
If you are getting salt its because youre filling while it is regenerating and the bypass is not working right. Soda blasting in a cabinet or enclosure want workout. pool maintenance companies have yet to adopt them, or bother to seek them out and learn them. u("pagespeed.CriticalImages.Run",function(b,c,a,d,e,f){var r=new y(b,c,a,e,f);x=r;d&&w(function(){window.setTimeout(function(){A(r)},0)})});})();
JavaScript is disabled. For doing something small this might be worth a try-. Oh, about the additional salt added from soft water.
$400 would have been more reasonable, but I couldn't talk them out of the "gas tax." The other fellow's pool was as you describe - thick, thick, thick calcium deposits and he had not only standard tile but also patterned tile (lion heads) as well. Takes a while, and you have to be really close to the work, but it does work well, and still a ton faster than manual methods. Not much money in it for a pool maintenance company when all they really need to do is test properly, use chlorine and MA and occasionally orchestrate a refill. Your system can handle up to 5000 ppm NaCl.
Rennlist Forum Glitches - post them here. function u(b,c){var a=b.split(". I'll do some research and report back if I come up with anything useful for TFPers No salt build up should happen. I used almost 120 lbs (about $100) for a 14000 gallon pool on 6x6 tile and rocks only. ("naturalWidth"in a&&"naturalHeight"in a))return{};for(var d=0;a=c[d];++d){var e=a.getAttribute("data-pagespeed-url-hash");e&&(! If, list on pages 14-15 to identify important, turn the switch to its off position after, Check for loose connections and make sure, , , quality and durability standards, and warrants to the original purchaser that this product, is free from defects in materials and workmanship for the period of one year from the, date of purchase (90 days if used by a professional contractor or if used as rental equip-, ment).
That was a concern. Me neither.
function A(b){b.b={};for(var c=["IMG","INPUT"],a=[],d=0;d
It is being practiced by thousands of pool owners just like you. Contact Us -
I refilled with too much soft water though so be careful there, I am now adding calcium chloride which kills me to get my CA to a balanced CSI number. Maxx Strip is the only way to go, I would never subject my pump to spurious glass beads, don't think you could ever get it all out. Advertising -
So that will be next ------. I went into the process of cleaning the engine bay with a steam machine, it was like pissing in the wind plus all the steam did to the greases were push them around. Well, as a reassurance, my CH is currently 1250ppm or almost 5X the lower limit recommended and Im able to keep my pool (under the water) completely scale free by managing the CSI closely. So want that to be true. For technical questions or replacement parts, please call 1-800-444-3353. ing, inspection, maintenance and cleaning, number in the back of the manual near the, this manual and the receipt in a safe and, , Install an in-line shutoff valve to allow, highly recommended whenever moisture level in, that the item is intact and undamaged.
The PF2 will etch plaster and grout but that was my technique and not an issue after my first tile.
Santa Monica or London, depending on work. I am not sure how much of an issue that is.
- Brushed Brass Flush Mount Light
- Fiber Laser Engraver For Sale
- Clergy Pectoral Crosses
- Side Mount Cordless Blinds
- Ultrasonic Degreasing Machine
- Thuraya Xt-lite Vs Xt-pro
- Print 5x7 Cards Walgreens
- Instant Deep Wrinkle Filler
- Postdoctoral Fellowship In Usa Salary
- Schedule 40 Reducing Elbow
- 15 Passenger Van Rental In Maryland
- Lenovo Ideapad Gaming I5
- Spiraflex Vacuum Hose
- 316 Stainless Steel Tube Sizes
- Chicago White Sox Custom Jersey
harbor freight soda blaster
You must be concrete block molds for sale to post a comment.